logo
products
PRODUCTS DETAILS
Home > Products >
0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge

MOQ: 100
Price: Negotiable
Standard Packaging: PE bag + box
Delivery Period: 21-30
Payment Method: L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal
Supply Capacity: 5000pc/month
Detail Information
Place of Origin
PRC
Brand Name
WECHANGE
Model Number
WF-PL-F-0045-30-A-S
OD:
68mm
Length:
30"
Filtration Rating:
0.45μm
Effective Filtration Area::
≥2.04m²/30"
MOQ:
100 Piece
Membrane Material:
PTFE
Shell & Core Material:
PP
Highlight:

PTFE Pharmaceutical Filter Cartridge

,

PTFE Pharmaceutical Filter Cartridge

,

PTFE cartridge filter

Product Description

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge

Description of Pharmaceutical Air Sterilization Filtration

PTFE membrane filters providing the utmost assurance of chemical resistance, durability and critical filtration performance in aggressive fluids.

WECHANGE PTFE(polytetrafluoroethylene) membrane filters cartridge offer the highest level of assurance of chemical compatibility and filtration performance in aggressive chemicals, prolonged hot air service and other severe process conditions.

Our products delivers superior flow rates and long service life. The highly porous membrane is inherently hydrophobic and offers maximum chemical compatibility with minimal extractables in a wide range of fluids and applications. Support components are all-polypropylene.

Application of Pharmaceutical Air Sterilization Filtration

  • Solvent and strong oxidizing liquid impurity filtration;
  • Aseptic air intake and exhaust filtration for fermentation, storage and ingredient tanks;
  • Air sterilization, food and beverage water filtration.
  • Sterile filtration of corrosive gases.
  • Photoresist filtration;
  • Liquid and air filtration in microelectronic industry.

Features of Pharmaceutical Air Sterilization Filtration

  • High flow rates and low pressure drops;
  • Consistent and reproducible particulate removal;
  • No media migration into the process fluid;
  • Provides excellent compatibility with a wide range of chemicals such as acids, bases, and solvents;
  • Integrity test for every pleated filter cartridge;
  • 100,000-level clean room manufactured;
  • 100% integrity test for every filter cartridge before delivery.

 

Operating Characteristic of Pharmaceutical Air Sterilization Filtration

Outer Diameter 2.7”/69mm
Length 5”/127mm 10”/254mm 20”/508mm 30”/762mm 40”/1016mm
Pore Size 0.1, 0.2, 0.45, 1.0, 3.0, 10μm
Max. Operation Temperature 80℃
Max. Operation Pressure

Forward direction: 0.5 MPa(25±2℃)

0.24MPa(80±2℃)

*It not recommend for reverse use

Filtration Areas

5”≥0.34m²; 10”≥0.68m²; 20”≥1.36m²

30”≥2.04m²; 40”≥2.72m²

Integrity Testing

Bubble Point≥60 KPa

Under 50 KPa,Diffusion flow<15 ml/min

25℃, ethanol as the wetting solution

Sterilization 30 times (121.4℃,30 min offline high-pressure steam sterilization)
Bacterial Retention Capacity

Minimum retention rate 107 CFU/cm2

The product was tested against Serratia marcescens (ATCC14756) using ASTM F838 method.

Extractable Substance

<50 mg/m2

After high-pressure steam sterilization(121.4℃,60 min), 25℃±2℃ immersing in pure water for 24h

Biosafety The endotoxin level<0.25 EU/ml, and the extraction solution has no acute toxicity
Cleanliness

No fibers or other visible foreign objects were detected in the filtered liquid.

*Lamp test according to the Chinese Pharmacopoeia 2020 edition <0904>

Flow Rate of Pharmaceutical Air Sterilization Filtration

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 0

Material of Structure of Pharmaceutical Air Sterilization Filtration

Filter Media PTFE
Deflector Layer Polypropylene
Enclosures/Ports High Temperature Resistance Polypropylene
Adapter Polypropylene
Seals Silicone/EPDM

Naming Regulations of Pharmaceutical Air Sterilization Filtration

WF PL F 0045 05 M S
Trademark Form Filtration Materials Accuracy length Adapter O ring
WECHANFIB PLEATED PTFE 0010 0.10μm 5 5” A 222/ FIN S Silicone
      0022 0.22μm 10 10” B 222/Flat End Cap E EPDM
      0045 0.45μm 20 20” C 226/ FIN V FKM
      0100 1μm 30 30” D 226/ Flat End Cap T PTFE
      0300 3μm 40 40” E DOE  
      1000 10μm      

 

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 1

Wechange Pleated Filter Cartridge Products List
Membrane Material Type No. Application Pore Size Diameter Length Adaptor
μm mm inch
PTFE WF-PL-F-0005-5-* Air Sterilization Filtration, Photoresist Filtration, Microelectronic Liquid Filtration, Semiconductor Process Gas Line Filtration, Crossive Solvent & Strong Oxidizing Liquid Impurity Filtration. 0.05 69 5"

The "*" Indicate type of CONNECTOR and SEAL RING, they're customizable and have below option codes:
1,Connector:
A 222/Fin
B 222/Flat End Cap
C 226/Fin
D 226/Flat End Cap
E DOE

2,Sealing Ring:
S Silicone
E EDPM(Ethylene
Propylene Diene
Monomer)
V FKM

(Fluororubber)
T PTFE(Polytetra-
fluoroethylene)

PTFE WF-PL-F-0005-10-* 0.05 69 10"
PTFE WF-PL-F-0005-20-* 0.05 69 20"
PTFE WF-PL-F-0005-30-* 0.05 69 30"
PTFE WF-PL-F-0005-40-* 0.05 69 40"
PTFE WF-PL-F-0010-5-* 0.1 69 5"
PTFE WF-PL-F-0010-10-* 0.1 69 10"
PTFE WF-PL-F-0010-20-* 0.1 69 20"
PTFE WF-PL-F-0010-30-* 0.1 69 30"
PTFE WF-PL-F-0010-40-* 0.1 69 40"
PTFE WF-PL-F-0020-5-* 0.2 69 5"
PTFE WF-PL-F-0020-10-* 0.2 69 10"
PTFE WF-PL-F-0020-20-* 0.2 69 20"
PTFE WF-PL-F-0020-30-* 0.2 69 30"
PTFE WF-PL-F-0020-40-* 0.2 69 40"
PTFE WF-PL-F-0045-5-* 0.45 69 5"
PTFE WF-PL-F-0045-10-* 0.45 69 10"
PTFE WF-PL-F-0045-20-* 0.45 69 20"
PTFE WF-PL-F-0045-30-* 0.45 69 30"
PTFE WF-PL-F-0045-40-* 0.45 69 40"
PTFE WF-PL-F-0100-5-* 1 69 5"
PTFE WF-PL-F-0100-10-* 1 69 10"
PTFE WF-PL-F-0100-20-* 1 69 20"
PTFE WF-PL-F-0100-30-* 1 69 30"
PTFE WF-PL-F-0100-40-* 1 69 40"
PTFE WF-PL-F-0300-5-* 3 69 5"
PTFE WF-PL-F-0300-10-* 3 69 10"
PTFE WF-PL-F-0300-20-* 3 69 20"
PTFE WF-PL-F-0300-30-* 3 69 30"
PTFE WF-PL-F-0300-40-* 3 69 40"
PTFE WF-PL-F-1000-5-* 10 69 5"
PTFE WF-PL-F-1000-10-* 10 69 10"
PTFE WF-PL-F-1000-20-* 10 69 20"
PTFE WF-PL-F-1000-30-* 10 69 30"
PTFE WF-PL-F-1000-40-* 10 69 40"

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 20.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 30.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 4

 

PTFE Membrane Filter Cartridge for Pharmaceutical Air Sterilization Filtration 0.45μm/30"

 

General Description of Pharmaceutical Air Sterilization Filtration

 

   PTFE membrane filter tubes used for pharmaceutical air sterilization filtration are crucial equipment for ensuring a sterile and highly efficient air purification environment in pharmaceutical production. Their design and application strictly adhere to industry standards and regulations to safeguard drug quality and production safety.

 

Application of Pharmaceutical Air Sterilization Filtration:

 

1.Solvent and strong oxidizing liquid impurity filtration

2.Aseptic air intake and exhaust filtration for fermentation, storage and ingredient tanks

3.Pre filtration of compressed air and nitrogen sterilization

 

Features and Benefits of Pharmaceutical Air Sterilization Filtration:

 

* PTFE membrane filter sleeves possess high-efficiency particulate filtration capabilities, effectively retaining bacteria, viruses, and suspended particles in the air, ensuring the purity of the air and meeting the pharmaceutical industry's requirements for a sterile environment;

* The design takes into account ease of installation, disassembly, and cleaning, ensuring long-term stable operation;

* To ensure the sterility of the final product, the manufacturing process is typically carried out in a sterile environment, using sterile materials and tools, and strictly controlling the risk of contamination during the production process;

* Strict quality control system, complete production process flow;

* Short delivery period;

* Flexible payment method: T/T, L/C, West Union, Paypal;

* Free technical support;

* Other specific sizes can be customized;

 

 

 

Performance Specifications of Pharmaceutical Air Sterilization Filtration:

 

Dimensions(nominal):

OD 69mm
Length

5"(127mm),10"(254mm),20"(508mm),30"(762mm)

 

Material of Construction:

Filter Media Deflector layer port Enclosures/Ports Seals Material

PTFE

Polypropylene Polypropylene

Polypropylene

Silastic/EPDM

 

Beer Clarification Filter Cartridge Performance:

Maximum operation temperature 80℃
Maximum operation pressure

Forward direction :0.5 MPa(25±2℃)

0.24MPa(80±2℃)

It not recommend for reverse use

Filtration areas

≥0.68 m²/ 10 inch

≥2.04 m²/ 30 inch

Integrity test

Bubble Point≥70 KPa

Under 50 KPa,Diffusion flow<15 ml/min

25℃, ethanol as the wetting solution

Sterilization 30 times(121.4℃,30 min offline high-pressure steam sterilization)
Bacteria interception

Minimum interception: 107 CFU/cm2

According to standard ASTM F838, Serratia marcescens (ATCC14756)

Extractable substance

<50 mg/m2

After high-pressure steam sterilization(121.4℃,60 min),25℃±2℃ immersing in pure water for 24h

Biosafety The endotoxin level<0.25 EU/ml, and the extraction solution has no acute toxicity
Cleanliness No fibers or other visible foreign objects were detected in the filtered liquid
products
PRODUCTS DETAILS
0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge
MOQ: 100
Price: Negotiable
Standard Packaging: PE bag + box
Delivery Period: 21-30
Payment Method: L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal
Supply Capacity: 5000pc/month
Detail Information
Place of Origin
PRC
Brand Name
WECHANGE
Model Number
WF-PL-F-0045-30-A-S
OD:
68mm
Length:
30"
Filtration Rating:
0.45μm
Effective Filtration Area::
≥2.04m²/30"
MOQ:
100 Piece
Membrane Material:
PTFE
Shell & Core Material:
PP
Minimum Order Quantity:
100
Price:
Negotiable
Packaging Details:
PE bag + box
Delivery Time:
21-30
Payment Terms:
L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal
Supply Ability:
5000pc/month
Highlight

PTFE Pharmaceutical Filter Cartridge

,

PTFE Pharmaceutical Filter Cartridge

,

PTFE cartridge filter

Product Description

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge

Description of Pharmaceutical Air Sterilization Filtration

PTFE membrane filters providing the utmost assurance of chemical resistance, durability and critical filtration performance in aggressive fluids.

WECHANGE PTFE(polytetrafluoroethylene) membrane filters cartridge offer the highest level of assurance of chemical compatibility and filtration performance in aggressive chemicals, prolonged hot air service and other severe process conditions.

Our products delivers superior flow rates and long service life. The highly porous membrane is inherently hydrophobic and offers maximum chemical compatibility with minimal extractables in a wide range of fluids and applications. Support components are all-polypropylene.

Application of Pharmaceutical Air Sterilization Filtration

  • Solvent and strong oxidizing liquid impurity filtration;
  • Aseptic air intake and exhaust filtration for fermentation, storage and ingredient tanks;
  • Air sterilization, food and beverage water filtration.
  • Sterile filtration of corrosive gases.
  • Photoresist filtration;
  • Liquid and air filtration in microelectronic industry.

Features of Pharmaceutical Air Sterilization Filtration

  • High flow rates and low pressure drops;
  • Consistent and reproducible particulate removal;
  • No media migration into the process fluid;
  • Provides excellent compatibility with a wide range of chemicals such as acids, bases, and solvents;
  • Integrity test for every pleated filter cartridge;
  • 100,000-level clean room manufactured;
  • 100% integrity test for every filter cartridge before delivery.

 

Operating Characteristic of Pharmaceutical Air Sterilization Filtration

Outer Diameter 2.7”/69mm
Length 5”/127mm 10”/254mm 20”/508mm 30”/762mm 40”/1016mm
Pore Size 0.1, 0.2, 0.45, 1.0, 3.0, 10μm
Max. Operation Temperature 80℃
Max. Operation Pressure

Forward direction: 0.5 MPa(25±2℃)

0.24MPa(80±2℃)

*It not recommend for reverse use

Filtration Areas

5”≥0.34m²; 10”≥0.68m²; 20”≥1.36m²

30”≥2.04m²; 40”≥2.72m²

Integrity Testing

Bubble Point≥60 KPa

Under 50 KPa,Diffusion flow<15 ml/min

25℃, ethanol as the wetting solution

Sterilization 30 times (121.4℃,30 min offline high-pressure steam sterilization)
Bacterial Retention Capacity

Minimum retention rate 107 CFU/cm2

The product was tested against Serratia marcescens (ATCC14756) using ASTM F838 method.

Extractable Substance

<50 mg/m2

After high-pressure steam sterilization(121.4℃,60 min), 25℃±2℃ immersing in pure water for 24h

Biosafety The endotoxin level<0.25 EU/ml, and the extraction solution has no acute toxicity
Cleanliness

No fibers or other visible foreign objects were detected in the filtered liquid.

*Lamp test according to the Chinese Pharmacopoeia 2020 edition <0904>

Flow Rate of Pharmaceutical Air Sterilization Filtration

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 0

Material of Structure of Pharmaceutical Air Sterilization Filtration

Filter Media PTFE
Deflector Layer Polypropylene
Enclosures/Ports High Temperature Resistance Polypropylene
Adapter Polypropylene
Seals Silicone/EPDM

Naming Regulations of Pharmaceutical Air Sterilization Filtration

WF PL F 0045 05 M S
Trademark Form Filtration Materials Accuracy length Adapter O ring
WECHANFIB PLEATED PTFE 0010 0.10μm 5 5” A 222/ FIN S Silicone
      0022 0.22μm 10 10” B 222/Flat End Cap E EPDM
      0045 0.45μm 20 20” C 226/ FIN V FKM
      0100 1μm 30 30” D 226/ Flat End Cap T PTFE
      0300 3μm 40 40” E DOE  
      1000 10μm      

 

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 1

Wechange Pleated Filter Cartridge Products List
Membrane Material Type No. Application Pore Size Diameter Length Adaptor
μm mm inch
PTFE WF-PL-F-0005-5-* Air Sterilization Filtration, Photoresist Filtration, Microelectronic Liquid Filtration, Semiconductor Process Gas Line Filtration, Crossive Solvent & Strong Oxidizing Liquid Impurity Filtration. 0.05 69 5"

The "*" Indicate type of CONNECTOR and SEAL RING, they're customizable and have below option codes:
1,Connector:
A 222/Fin
B 222/Flat End Cap
C 226/Fin
D 226/Flat End Cap
E DOE

2,Sealing Ring:
S Silicone
E EDPM(Ethylene
Propylene Diene
Monomer)
V FKM

(Fluororubber)
T PTFE(Polytetra-
fluoroethylene)

PTFE WF-PL-F-0005-10-* 0.05 69 10"
PTFE WF-PL-F-0005-20-* 0.05 69 20"
PTFE WF-PL-F-0005-30-* 0.05 69 30"
PTFE WF-PL-F-0005-40-* 0.05 69 40"
PTFE WF-PL-F-0010-5-* 0.1 69 5"
PTFE WF-PL-F-0010-10-* 0.1 69 10"
PTFE WF-PL-F-0010-20-* 0.1 69 20"
PTFE WF-PL-F-0010-30-* 0.1 69 30"
PTFE WF-PL-F-0010-40-* 0.1 69 40"
PTFE WF-PL-F-0020-5-* 0.2 69 5"
PTFE WF-PL-F-0020-10-* 0.2 69 10"
PTFE WF-PL-F-0020-20-* 0.2 69 20"
PTFE WF-PL-F-0020-30-* 0.2 69 30"
PTFE WF-PL-F-0020-40-* 0.2 69 40"
PTFE WF-PL-F-0045-5-* 0.45 69 5"
PTFE WF-PL-F-0045-10-* 0.45 69 10"
PTFE WF-PL-F-0045-20-* 0.45 69 20"
PTFE WF-PL-F-0045-30-* 0.45 69 30"
PTFE WF-PL-F-0045-40-* 0.45 69 40"
PTFE WF-PL-F-0100-5-* 1 69 5"
PTFE WF-PL-F-0100-10-* 1 69 10"
PTFE WF-PL-F-0100-20-* 1 69 20"
PTFE WF-PL-F-0100-30-* 1 69 30"
PTFE WF-PL-F-0100-40-* 1 69 40"
PTFE WF-PL-F-0300-5-* 3 69 5"
PTFE WF-PL-F-0300-10-* 3 69 10"
PTFE WF-PL-F-0300-20-* 3 69 20"
PTFE WF-PL-F-0300-30-* 3 69 30"
PTFE WF-PL-F-0300-40-* 3 69 40"
PTFE WF-PL-F-1000-5-* 10 69 5"
PTFE WF-PL-F-1000-10-* 10 69 10"
PTFE WF-PL-F-1000-20-* 10 69 20"
PTFE WF-PL-F-1000-30-* 10 69 30"
PTFE WF-PL-F-1000-40-* 10 69 40"

0.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 20.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 30.45μM 30" PTFE Cartridge Filter Pharmaceutical Filter Cartridge 4

 

PTFE Membrane Filter Cartridge for Pharmaceutical Air Sterilization Filtration 0.45μm/30"

 

General Description of Pharmaceutical Air Sterilization Filtration

 

   PTFE membrane filter tubes used for pharmaceutical air sterilization filtration are crucial equipment for ensuring a sterile and highly efficient air purification environment in pharmaceutical production. Their design and application strictly adhere to industry standards and regulations to safeguard drug quality and production safety.

 

Application of Pharmaceutical Air Sterilization Filtration:

 

1.Solvent and strong oxidizing liquid impurity filtration

2.Aseptic air intake and exhaust filtration for fermentation, storage and ingredient tanks

3.Pre filtration of compressed air and nitrogen sterilization

 

Features and Benefits of Pharmaceutical Air Sterilization Filtration:

 

* PTFE membrane filter sleeves possess high-efficiency particulate filtration capabilities, effectively retaining bacteria, viruses, and suspended particles in the air, ensuring the purity of the air and meeting the pharmaceutical industry's requirements for a sterile environment;

* The design takes into account ease of installation, disassembly, and cleaning, ensuring long-term stable operation;

* To ensure the sterility of the final product, the manufacturing process is typically carried out in a sterile environment, using sterile materials and tools, and strictly controlling the risk of contamination during the production process;

* Strict quality control system, complete production process flow;

* Short delivery period;

* Flexible payment method: T/T, L/C, West Union, Paypal;

* Free technical support;

* Other specific sizes can be customized;

 

 

 

Performance Specifications of Pharmaceutical Air Sterilization Filtration:

 

Dimensions(nominal):

OD 69mm
Length

5"(127mm),10"(254mm),20"(508mm),30"(762mm)

 

Material of Construction:

Filter Media Deflector layer port Enclosures/Ports Seals Material

PTFE

Polypropylene Polypropylene

Polypropylene

Silastic/EPDM

 

Beer Clarification Filter Cartridge Performance:

Maximum operation temperature 80℃
Maximum operation pressure

Forward direction :0.5 MPa(25±2℃)

0.24MPa(80±2℃)

It not recommend for reverse use

Filtration areas

≥0.68 m²/ 10 inch

≥2.04 m²/ 30 inch

Integrity test

Bubble Point≥70 KPa

Under 50 KPa,Diffusion flow<15 ml/min

25℃, ethanol as the wetting solution

Sterilization 30 times(121.4℃,30 min offline high-pressure steam sterilization)
Bacteria interception

Minimum interception: 107 CFU/cm2

According to standard ASTM F838, Serratia marcescens (ATCC14756)

Extractable substance

<50 mg/m2

After high-pressure steam sterilization(121.4℃,60 min),25℃±2℃ immersing in pure water for 24h

Biosafety The endotoxin level<0.25 EU/ml, and the extraction solution has no acute toxicity
Cleanliness No fibers or other visible foreign objects were detected in the filtered liquid